Anesthesia

Anes V30 Anesthesia Machine
• Gas Source: Medical oxygen • Nominal supply pressure: 400±50 kPa • Oxygen Flow Meter Configuration 1 (standard): 0.1-4 L/min • Configuration 2 (optional): 0.1-10 L/min • Evaporator Configuration 1 (standard): isoflurane evaporator • Configuration 2 (optional): sevoflurane evaporator • Output concentration range and accuracy: - Isoflurane evaporator: 0.2-5%; accuracy: ±0.20% volume or ±20% relative - Sevoflurane evaporator: 0.2-8%; Accuracy: ±0.20% volume or ±20% relative • Oxygen Flow: 30-50 L/min • CO2 Absorber Reservoir (optional) ≥1000 ml • Operating Conditions Ambient temperature: 10°C to 40°C • Relative humidity: 15% to 95%, non-condensing • Pressure head: 60.0 kPa to 110.0 kPa • Dimensions: - Entire machine (without trolley): 465 mm (W) × 435 mm (H) × 370 mm (D) - Entire machine (with trolley): 465 mm (W) × 1285 mm (H) × 370 mm (Diameter) • Weight of the entire machine (excluding trolley): 18.5 kg • Weight of the entire machine (including trolley): 25.4 kg • Service Life: 10 years

Anes V60 Anesthesia Machine
• Provides precise ventilation by supporting a minimum tidal volume of up to 5 ml. • Supports automatic pre-set tidal volume adjustment according to animal weight. • Enhances ventilation comfort by supporting spontaneous breathing. • Supports backup ventilation for animal safety. TECHNICAL SPECIFICATIONS • Dimensions (W×H×D): 410 mm×620 mm×360 mm • Net weight: approx. 30 kg (excluding cart and accessories) • Maximum weight: 73 kg • Display: 8.4-inch touchscreen • Service life: 10 years (excluding battery and oxygen sensor) • Operating conditions: Ambient temperature: 15 ℃ - 30 ℃ • Ambient humidity: 10% - 85% • Atmospheric pressure: 70 kPa - 106 kPa • AC power input: 200-240V, 0.6A; 50/60 Hz • Battery: - Specification: DC 12V; 2.8 Ah - Operating time: ≥60 min (Test condition: Fully charged new battery, VC ventilation mode, bpm= 10, I:E ratio= 1:2, TV= 500 mL), PEEP OFF, Pressure limit= 40 cmH2O, Inspiration pause= 0%, Gas supply = 0.4±0.1MPa) - Charging time: ≥14 hours (when switched off) • Maximum heater power: - Heater for breathing circuit: 45W - Heater for Spirobox flow sensor: 3W • Source gas pressure: 280 - 600 kPa • Oxygen flow: 10 L/min - 15 L/min • Flow range: 0 - 10 L/min • Ventilator Monitoring Parameters: - Airway pressure monitoring range: -20 cmH2O to 99 cmH2O - Tidal Volume Monitoring Range: 0 mL to 2000 mL - Minute Volume Monitoring Range: 0 L to 50 L - O2 Concentration Monitoring Range: 0% to 100% - Respiratory Rate Monitoring Range: 4 bpm - 120 bpm - I:E Ratio Monitoring Range: 1:0.2 - 1:8.0 Control Parameters • Tidal Volume (VT) Range: 5 mL - 1600 mL • Respiratory Rate Range: 4 bpm - 100 bpm • Accuracy: ±1 bpm or ±5% of the set value (whichever is greater) • I:E Ratio Range: 1:0.2 - 1:8.0
HA-3300B Anesthesia Machine
• The Anesthesia Machine is an indispensable anesthesia device in the operating room. • Its function is: - To provide oxygen and anesthetic to a patient requiring anesthesia for surgery and to manage ventilation. • The Anesthesia Machine is equipped with a sensitive, specialized anesthetic vaporizer and a safety device and necessary alarm system to prevent cyanosis. • During anesthesia, the patient's respiratory functions can be managed using a microcomputer-controlled pneumatic-electric-controlled synchronized anesthesia ventilator. • All connection parts of the device are a standard interface. • A high-efficiency, large-volume soda lime absorber can minimize the patient's re-breathing of carbon dioxide. • Operating conditions: - Ambient temperature: 10 ~ 40 ℃; - Relative humidity: Should not exceed 80%; - Atmospheric pressure: 860 hPa ~ 1060 hPa - Power requirement: ~220-240V, 50/60Hz, 40VA, must be well grounded. - Air source requirement: Medical oxygen with a nominal pressure between 0.3 and 0.5 MPa • Caution: The AC power supply used for the anesthesia machine must be well grounded.